All divisions

DIVISION 03

ELV / Low Current & ICT

One accountable party designs, installs, integrates and documents — one dossier at handover

The division

Low-current systems are the intelligent layer of every building — the controls, security, networks and sound no shell or plant can work without. Six system sub-divisions, one profit centre, one dossier at handover.

It is the division the company configured first — and the one where packages most often come apart: cabling belongs to one trade, controllers to another, the head-end to a third, and the interfaces to nobody. Here all six sit in one division, priced as one package and proven as one system. We build on published, multi-vendor protocols, so the installation can be extended, re-tendered or maintained without coming back to us. It works inside the same matrix organisation, the same four walls and the same system of record as every other package.

See all projects

Six systems, one division

Six systems, one division, one price. Each system is a sub-division with its own scope lines, and on a whole-building package they are quoted, installed, integrated and documented together — by one team, against one programme.

BMS / BAS (incl. KNX)

Controllers, field devices and a head-end supervising plant, lighting and energy — on open protocols.

  • HVAC and plant control points
  • KNX lighting, shading and room control
  • Energy metering and trend logs
  • Head-end graphics, alarms and scheduling
  • Points list and cause-and-effect matrix maintained to the as-built

CCTV & security / access control

Cameras, recorders, intrusion detection and access control as one layer — one operator view, one event log.

  • IP CCTV and video recording
  • Card, PIN and biometric access control
  • Intrusion detection and device maintenance
  • Storage sized to the retention the specification sets
  • Doors, readers and interlocks coordinated with the architectural package

Parking management

Barriers, ticketing or plate recognition, counting and guidance — tied into access control and the network.

  • Barriers, lane controllers and pay stations
  • Number-plate recognition and space counting
  • Guidance signage and traffic-safety devices
  • Occupancy counts published to the signage and to the head-end
  • Resident, staff and visitor rules set with the building's operator

Structured cabling, networks & ICT

Copper and fibre, racks, containment, switching and wireless — tested, labelled and documented link by link.

  • Copper and fibre cabling, test results recorded
  • Data, telecom and TV distribution networks
  • Switching, Wi-Fi and server-room fit-out
  • Racks, patch schedules and containment coordinated with civil and MEP
  • Every link labelled at both ends to one agreed scheme

Audio-visual & public address

Sound, display and public address for lobbies, halls, prayer and meeting rooms — zoned from one interface.

  • Public-address and background-music zoning
  • Meeting-room and auditorium AV
  • Master-antenna TV and satellite distribution
  • Announcement priority and volume set zone by zone
  • Amplifiers, racks and loudspeaker layouts sized room by room

Fire-alarm interfaces — integration only

We do not install fire-alarm systems; we integrate them — cause-and-effect interfaces to BMS, access control, lifts and public address.

Integration only

  • Alarm signals mapped into cause-and-effect
  • Early-warning siren and control-centre interfaces
  • Installation coordinated with Civil Defense-licensed specialists
  • Lift homing, door release and ventilation signals proven with that specialist
  • Every interface test witnessed and recorded in the dossier

The sixth card is the boundary, not a gap: fire alarm is an interface here, never an offer. We integrate it; installation stays with Civil Defense-licensed specialists.

Codes, tests and the open-protocol position

The Saudi Building Code 2024 energy-conservation provisions make metered, controlled energy use a design requirement; a commissioned building-management system is where that requirement is proven.

Testing and labelling

Structured cabling is where a low-current package is won or lost. Every copper and fibre link is tested to the parameters the specification sets, labelled at both ends to one scheme agreed before the first cable is pulled, and recorded against its link identifier, its date and its result. A link with no test record is not a finished link.

The open-protocol position

BACnet · Modbus · KNX · MQTT

We build on open protocols — BACnet, Modbus, KNX and MQTT — and we are tied to no manufacturer: we hold no manufacturer accreditation and will not print one. The brands we work with are listed on their own page, for orientation. Where your specification requires a manufacturer's accredited installer, we say so at tender and coordinate that scope with a specialist who holds it. What you are left holding is a system another contractor could extend, re-tender or maintain.

The division's installed scope sits in one family of the company's commercial registration — eight of the 101 registered activities, printed here so you can check them against your package before you invite us. The fire-alarm interface sits in a ninth code in another family, and is integration only.

CodeRegistered activity
432111Electrical wiring
432112Telecom wiring
432113Network wiring
432121TV and satellite networks
432122Computer and telecom networks
432131Lighting systems
432134Security devices — installation and maintenance
432135Traffic-safety devices

At handover you get one dossier, not six: as-builts, test records, points lists, credentials and training, issued once by the division that installed the work.

DIVISION 03 · ARTIFICIAL INTELLIGENCE

AI features we configure and commission

CCTV and video surveillance

  • People and vehicle classification that filters false motion alarms
  • Virtual lines, restricted zones and loitering alerts for people and vehicles
  • People counting, occupancy levels and heat maps of where people gather and linger
  • Number-plate reading (ANPR) with allow and block lists driving the vehicle barrier
  • Face recognition on the recorder against enrolled lists, with match alerts
  • Plain-language recording search in Arabic or English, and search by clothing or vehicle colour

Structured cabling, networks and telephony

  • Anomaly detection across wired and Wi-Fi networks, with root cause and suggested fix
  • Faulty cable, port and PoE detection by learning each link's normal behaviour
  • Automatic Wi-Fi channel, width and power tuning from the site's radio history, reducing interference
  • Energy saving that idles access points in quiet hours, from learned usage patterns
  • Background-noise suppression on desk-phone calls for clearer speech in busy offices
  • Call and voicemail transcription with automatic call summaries on the IP PBX

Security, access control and intrusion

  • Face and palm recognition with liveness detection that rejects photos, screens and masks
  • Tailgating and piggybacking detection by 3D sensing, with a live headcount per lane
  • Detector alarms verified by paired cameras that classify people, animals and vehicles
  • Camera-based sound classification of breaking glass, screams and shouts, alongside glass-break detectors
  • Face recognition entry at the door station, with liveness checks against photo spoofing
  • Visitor and parcel detection at the door, with alerts to indoor monitor and phone

Smart home and room control

  • mmWave radar presence detection that learns the room and ignores fans and similar interference
  • Camera-free fall detection by radar, with instant alerts to family or care staff
  • Natural-language voice control of lights, curtains, climate and scenes
  • Usage-pattern learning that suggests routines and turns off devices left on
  • AI air-conditioner optimisation via an IR controller, with open-window and efficiency alerts
  • 3D face or palm-vein unlocking with liveness checks that reject photos and masks

Features of current mainstream equipment, configured and commissioned to your specification; some need a licence or a server.

DIVISION 03 · THE SYSTEMS

Brands we work with

We are tied to no manufacturer. We specify, procure, install and commission equipment from the makers your specification names — among them the established brands below, grouped by system.

CCTV, recorders and video management

Axis · IQSIGHT (formerly Bosch) · Hanwha Vision · Avigilon · Pelco · Hikvision · Dahua · Uniview · Milestone · Genetec

Switching, routing and Wi-Fi

Cisco · HPE Aruba Networking · Huawei · Extreme Networks · RUCKUS Networks · Alcatel-Lucent Enterprise · Ubiquiti · TP-Link Omada

Structured cabling

CommScope · Panduit · Corning · Siemon · Legrand · Leviton

Network security

Fortinet · Palo Alto Networks · Cisco · Sophos · WatchGuard · SonicWall

IP telephony and unified communications

Cisco · Avaya · Alcatel-Lucent Enterprise · HP Poly · Yealink · Grandstream · Fanvil · 3CX

Access control and biometrics

HID Global · Honeywell · Suprema · ZKTeco · Gallagher · Salto · dormakaba · Hikvision

Intrusion detection

DSC · Honeywell · Paradox · Ajax Systems · Hikvision · Optex

Video intercom, turnstiles and speed gates

Aiphone · 2N · Commax · Dahua · Akuvox · Gunnebo · Boon Edam · dormakaba · CAME · Magnetic

Building management systems (BMS)

Siemens · Schneider Electric · Honeywell · Johnson Controls · Trane · Carrier · Distech Controls · SAUTER

KNX lighting, shading and room control

ABB · Siemens · Schneider Electric · Hager · Gira · JUNG · Zennio

Smart home and room automation

Control4 · Crestron · Lutron · Legrand · Somfy · HDL · Aqara

Audio-visual and public address

Bose Professional · Bosch · TOA · Yamaha · Shure · Extron · JBL Professional · Samsung

Parking management and barriers

SKIDATA · Scheidt & Bachmann · HUB Parking · Magnetic · CAME · Nice · Hikvision · Dahua

UPS and standby power

APC · Eaton · Vertiv · ABB · Socomec · Huawei · Delta Electronics · CSB

Brand names are their owners' trademarks, listed for orientation. No exclusive tie, dealership or manufacturer accreditation is claimed; where a specification requires one, we say so at tender.

Ministry of Commerce — Main Building

Systems and past work

These projects were delivered by our team's engineers and crews over their careers, before Engineering Horizon was registered. The photographs are from their own records.

Send us the tender drawings and bill of quantities

You get a priced package with one name accountable for it.

Talk to us